Applicable engines
|
Gasoline engines
2-cycle (1, 2, 3, 4 cylinders), 4-cycle (1, 2, 3, 4, 5, 6, 7, 8, 10, 12 cylinders)
|
Detection method
|
Electromagnetic induction
|
Detection distance
|
10 to 200 mm
|
Object of measurement
|
Ignition coil
|
Calculation method
|
Cycle calculation method
|
Measurement time
|
Within 1 s + the time required for one cycle
|
Display
|
5-digit LCD, with backlight (character height: 10.2 mm)
|
Display update time
|
1 ±0.2 s
|
Measurement units
|
r/min, r/s
|
Measurement ranges
|
2-cycle
|
4-cycle
|
Number of rotations (r/min)
|
-
|
1 cylinder
|
120 to 20000r/min
|
1cylinder
|
2 cylinders
|
120 to 20000r/min
|
-
|
3 cylinders
|
120 to 20000r/min
|
2 cylinders
|
4 cylinders
|
120 to 20000r/min
|
-
|
5 cylinders
|
120 to 20000r/min
|
3 cylinders
|
6 cylinders
|
120 to 15000r/min
|
4 cylinders
|
8 cylinders
|
120 to 12000r/min
|
-
|
10 cylinders
|
120 to 10000r/min
|
-
|
12 cylinders
|
120 to 8000r/min
|
(r/s is the numerical value obtained when the r/min measurement value is divided by 60)
|
Measurement accuracy
|
Displayed value* x (±0.02%) ±1 count
* The displayed value is the count value excluding figures after the decimal point.
|
Memory function
|
20 data (MAX)
|
Over-range function
|
The over-range alarm (ERROR mark) is displayed when the measured value exceeds the display range.
|
Rotation upper limit alarm function
|
The upper limit alarm ( mark) is displayed when the number of rotations exceeds the preset upper limit value.
|
Sensitivity adjustment function
|
A rotary dial at the right-hand side of the device is used to adjust the sensitivity.
|
Analog output
|
Output with respect to the displayed rotation values
Output voltage: 0 to 1 V/0 to FS (FS is freely selectable)
Conversion method: 10-bit D/A conversion
Linearity: ±1%/FS
Output update time: Within 50 ms + the time required for 1 cycle
Temperature stability: ±0.05%/FS/°C (span & zero)
Setting error: ±0.5%/FS
Load resistance: At least 100 kΩ
|
Monitor output
|
Analog output for monitoring purposes after waveform reshaping of the sensor signal
Load resistance: At least 100 kΩ
|
Pulse output
|
1 pulse output per signal detection
Output voltage: Hi level: At least +4.5, Lo level: Up to +0.5 V
Output logic: Positive logic
Load resistance: At least 100 kΩ
|
Power source
|
Four AAA alkaline batteries or exclusive AC adapter (PB-7090, Option)
|
Battery life
|
At least 32 hours (when the backlight is OFF)
At least 8 hours (when the backlight is ON)
|
Low battery alarm indicator
|
A low battery alarm (LOW mark) is displayed when the battery voltage falls below 4.4 V.
|
Operating temperature range
|
0 to 40°C
|
Storage temperature range
|
-10 to 50°C
|
Outer dimensions
|
198.5 (W) x 47.5 (H) x 66 (D) mm
|
Weight
|
Approx. 300 g (including batteries)
|
Accessories
|
Ignition detector (IP-2800) , AAA alkaline batteries × 4, Carrying case
|