Casing: |
Protection class |
Dimensions |
Weight |
Connectors |
|
|
IP67 |
175 x 80 x 55mm |
1,1kg |
Circular plug-in connector with inserted nuts, Binder Serie 723 |
|
Power supply: |
|
External |
Power consumption: |
Sleep (between the measurements) |
Idle (active, but no measurement) |
During the measurement
|
During the data communication |
|
10..24V/DC (12V recommended) |
|
approx. 0,1mA |
approx. 10mA |
approx. 35mA (only Logger, sensors according to configuration of the system) |
- 30..50mA according to network quality |
|
Temperature: |
|
|
from -40 to +60°C |
from -20 to +60°C (sub-limit selectable, lower than -10°C with limited functionality) |
|
On-site data transmission: |
|
Interface |
Required Software |
Required Hardware |
|
RS232 |
GlobeLogControl |
Windows-PC with Windows2000 or higher |
|
Remote data transmission: |
|
Hardware |
Data service |
Transfer protocol |
Transfering costs (daily data transmission)
|
required Software (for remote maintenance and data storage) |
required Hardware |
|
Internal Quad-Band GSM-Modem |
GSM/GPRS |
http |
Lower than 1€ (in Germany, country-specific, nevertheless you have to pay only for local connection) |
GlobeLogControl
|
Windows-PC with Internet access, Windows2000 or higher, data will be transfered via e-mail by the globeLog Logger |
|
Data storage/Data logging: |
|
Storage type
|
Memory size |
Organisation
|
Measuring interval |
Number of measured data |
Erasing of measured data |
|
Data memory Flash (non-volatile memory) |
2MB |
Data will be recorded until the memory is full. Further accumulating data will be lost |
1min..12h |
- >250.000 |
on-site or via remote data transmission DFÜ (optional) |
|
Input channels: |
|
IMP-Bus 1-4
|
IMP-Bus 1-3
|
IMP-Bus 4
|
Housekeeping channels |
|
Up to 48 channels (Sensors can be up to 3-channels) |
For Sensors with switched supply voltage (is switched of between the measurements) |
For Sensors with permanent voltage |
- 1x internal temperature
- 1x supply voltage
- 1x voltage of back-up battery |
|
Internal Clock: |
|
Type |
Accuracy
|
Synchronisation |
On-site
|
Remote data transmission
|
Power supply |
|
Real-time clock |
maximum aberration 2 sec per day (adjustable in sensitivity depending on ambient temperature) |
|
manual with GlogLogControl Software |
automatically while each data transmission |
via supply voltage; during a power failure on the internal buffer battery (lifetime 4-6 years) |
|
Accessories: |
|
Power cord
|
RS232-cord
|
CD with GlobeLogControl Software |
Manual |
|
2m with 5-pol Binder connector and 2x Banana plug |
6-pol Binder connector und DB9 connector |
Windows2000 oder higher |
English |
|